Re: 2811 FT1 Issue [7:132338] posted 08/21/2008
[Chronological Index] [Thread Index] [Top] [Date Prev][Date Next] [Thread Prev][Thread Next]


That is what I figured. Thank you again for your assistance.

On Thu, Aug 21, 2008 at 10:37 AM, Fred Damstra wrote:

> You cannot.  A T1 is a different interface than ethernet.
>
> You can connect the ethernet port on the router to the switch, but not the
> T1 port.
>
> On Thu, Aug 21, 2008 at 8:41 AM, RS  wrote:
>
> > Another question in regards to the WIC-1DSU-T1-V2 is what do I need to do
> > to
> > connect it to a standard layer 2 cisco switch? Can I directly connect
> from
> > the WIC to the switch?
> >
> > On Thu, Aug 21, 2008 at 8:32 AM, RS  wrote:
> >
> > > Yes this was the issue. Thanks for the direction.
> > > Thanks,
> > > Richard
> > >
> > >
> > > On Thu, Aug 21, 2008 at 8:22 AM, RS  wrote:
> > >
> > >> Yes, this is in a lab. I will have to look up the standard T1
> crossover
> > >> setup and test it out.
> > >> Thanks,
> > >> Richard
> > >>
> > >> On Wed, Aug 20, 2008 at 6:39 PM, Fred Damstra wrote:
> > >>
> > >> > Is this in a lab?  If so, make sure you're using a T1 crossover
> cable.
> > >>  It
> > >> > is not the same as an ethernet crossover.
> > >> >
> > >> > If this is a physical T1, verify settings with the provider.
> > >> >
> > >> > On Wed, Aug 20, 2008 at 3:26 PM, RS  wrote:
> > >> >
> > >> > > I cannot get two FT1 (WIC-1DSU-T1-V2) to communicate between two
> > >> 2811s.
> > >> > >
> > >> > > Here is the config on
> > >> > > R1:
> > >> > > interface Serial0/0/0
> > >> > >  ip address 192.168.20.253 255.255.255.252
> > >> > >  service-module t1 clock source internal
> > >> > > end
> > >> > >
> > >> > > R2:
> > >> > > interface Serial0/2/0
> > >> > >  ip address 192.168.20.254 255.255.255.252
> > >> > > end
> > >> > >
> > >> > > Also R1 has "clock source internal" and R2 is "clock source line".
> > >> Both
> > >> > > have:
> > >> > >
> > >> > > framing esf
> > >> > > linecode b8zs
> > >> > > data-coding normal
> > >> > > timeslots all speed 64
> > >> > > encapsulation hdlc
> > >> > > no shut
> > >> > >
> > >> > > Other useful info:
> > >> > >  show service-module:
> > >> > >  Module type is T1/fractional
> > >> > >
> > >> > >  show int s0/2/0
> > >> > >  Serial0/2/0 is down, line protocol is down
> > >> > >  Encapsulation HDLC
> > >> > >  Keepalive set (10 sec)
> > >> > >
> > >> > >  show int s0/0/0
> > >> > >  Serial0/0/0 is down, line protocol is down
> > >> > >  Encapsulation HDLC
> > >> > >  Keepalive set (10 sec)
> > >> > >
> > >> > > Any ideas???
> > >> > > Thanks,
> > >> > > Richard




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=132354&t=132338
--------------------------------------------------